ThresholdConfiguration
Defines the failure threshold that the deployment circuit breaker uses to monitor a deployment. The type and value together determine the number of task failures that are tolerated before the circuit breaker triggers.
By default, the threshold configuration uses a type of BOUNDED_PERCENT with a value of 50.
Types
Properties
Determines how Amazon ECS uses value to calculate the failure threshold. For the percentage types (BOUNDED_PERCENT and UNBOUNDED_PERCENT), Amazon ECS multiplies value by the latest service desired count. For COUNT, Amazon ECS uses value directly as the threshold. The default is BOUNDED_PERCENT.
Specifies the integer that Amazon ECS uses to calculate the failure threshold. When type is COUNT, this value is the failure threshold itself. When type is a percentage type, Amazon ECS multiplies this value by the latest service desired count to produce the failure threshold. The default is 50.