AWS IoT Commands Troubleshooting - AWS IoT Core

AWS IoT Commands Troubleshooting

This is the troubleshooting section for AWS IoT Device Management Commands.

Command execution issues

Command execution stays in CREATED status

When a command execution remains in CREATED status and does not proceed to IN_PROGRESS or another status, consider the following:

  • Verify the device is connected to AWS IoT Core and has subscribed to the commands request topic.

  • Check that the device policy allows iot:Subscribe and iot:Receive on the commands request topic, and iot:Publish on the commands response topic.

  • If the device is offline and uses MQTT persistent sessions, the command waits at AWS IoT Core. When the device reconnects before the persistent session timeout and execution timeout, it can process the command. If the execution timeout expires, the execution transitions to TIMED_OUT.

DataConflict error on UpdateCommandExecution

A DataConflict error occurs when multiple UpdateCommandExecution requests are made to the service in parallel or within a short timeframe (for example, IN_PROGRESS followed immediately by SUCCEEDED).

To resolve this issue:

  • Subscribe to the /accepted and /rejected response topics to confirm each status update was processed before sending the next one.

  • Implement retry logic with exponential backoff when receiving DataConflict errors.

Command executions move to a TIMED_OUT terminal status unexpectedly

When a command execution transitions to TIMED_OUT before the device can process it:

  • Review the timeout value configured for the command execution. The default timeout may be too short for your use case.

  • If the device was offline when the command was sent, verify that the device reconnected and received the execution request before the timeout expired.

  • A cloud-initiated TIMED_OUT is non-terminal. The device can still update the execution to a terminal status (SUCCEEDED, FAILED, REJECTED, or TIMED_OUT).

Note

A device-initiated TIMED_OUT is a terminal status and no further updates can be made to this command execution.

How do I view errors in CloudWatch logs?

Errors from the UpdateCommandExecution MQTT request are logged in the AWSIoTLogsV2 log group in Amazon CloudWatch. To enable logging and view the logs, see Configure AWS IoT logging.

UpdateCommandExecution error codes

When the UpdateCommandExecution MQTT request fails, the service publishes an error response to the /rejected topic. The error response contains an error code and message. The following table lists the error codes that can be returned.

Error code Retryable Description
InvalidStateTransition No The requested status transition is not allowed. For example, transitioning from SUCCEEDED to IN_PROGRESS, updating a device-initiated TIMED_OUT execution.
TerminalStateReached No The command execution has already reached a terminal state and cannot be updated.
ResourceNotFound No The specified command execution does not exist.
DataConflict Yes The command execution was modified concurrently. This can occur when status updates are sent in rapid succession. Subscribe to the /accepted and /rejected response topics to confirm each status update was processed before sending the next one. For more details, see DataConflict error on UpdateCommandExecution.
InternalError Yes An internal server error occurred. Retry the request with exponential backoff.

The following is an example of an error response published to the /rejected topic:

{ "clientToken": "client-token-1", "executionId": "2bd65c51-4cfd-49e4-9310-d5cbfdbc8554", "error": "DataConflict", "errorMessage": "The command execution was modified concurrently" }