AlarmSummary
Contains a summary of an alarm.
Contents
- alarmModelName
-
The name of the alarm model.
Type: String
Length Constraints: Minimum length of 1. Maximum length of 128.
Pattern:
^[a-zA-Z0-9_-]+$Required: No
- alarmModelVersion
-
The version of the alarm model.
Type: String
Length Constraints: Minimum length of 1. Maximum length of 128.
Required: No
- creationTime
-
The time the alarm was created, in the Unix epoch format.
Type: Timestamp
Required: No
- keyValue
-
The value of the key used as a filter to select only the alarms associated with the key.
Type: String
Length Constraints: Minimum length of 1. Maximum length of 128.
Pattern:
^[a-zA-Z0-9\-_:]+$Required: No
- lastUpdateTime
-
The time the alarm was last updated, in the Unix epoch format.
Type: Timestamp
Required: No
- stateName
-
The name of the alarm state. The state name can be one of the following values:
-
DISABLED- When the alarm is in theDISABLEDstate, it isn't ready to evaluate data. To enable the alarm, you must change the alarm to theNORMALstate. -
NORMAL- When the alarm is in theNORMALstate, it's ready to evaluate data. -
ACTIVE- If the alarm is in theACTIVEstate, the alarm is invoked. -
ACKNOWLEDGED- When the alarm is in theACKNOWLEDGEDstate, the alarm was invoked and you acknowledged the alarm. -
SNOOZE_DISABLED- When the alarm is in theSNOOZE_DISABLEDstate, the alarm is disabled for a specified period of time. After the snooze time, the alarm automatically changes to theNORMALstate. -
LATCHED- When the alarm is in theLATCHEDstate, the alarm was invoked. However, the data that the alarm is currently evaluating is within the specified range. To change the alarm to theNORMALstate, you must acknowledge the alarm.
Type: String
Valid Values:
DISABLED | NORMAL | ACTIVE | ACKNOWLEDGED | SNOOZE_DISABLED | LATCHEDRequired: No
-