Store and forward issues
Important
Access to certain AWS IoT FleetWise features is currently gated. For more information, see AWS Region and feature availability in AWS IoT FleetWise.
Issue: Receiving an
AccessDeniedException with all required IAM
permissions
Solution: The store and forward feature for data partitioning in campaigns requires gated access through allow listing. Contact the service team to ensure that your resources have adequate permissions through allow listing.
Issue: The data uploaded to AWS IoT
Jobs ignores the endTime
Solution: You have specified an invalid endtime in the job document. For
example, the endtime doesn't following ISO 8601 UTC format). On AWS IoT FleetWise
Agent logs, there could be a warning-level statement that says, Malformed IoT
Job endTime: .customer configured endTime. Not setting
endTime
Issue: The data upload to AWS IoT
Jobs has a REJECTED execution status.
Solution: You have specified an invalid campaignArn in the job document. For
example, if you specify an ARN for a campaign that is not running on a vehicle,
there could be a error-level statement that says, CampaignArn value in the
received job document does not match the ARN of a Store and Forward
campaign in the AWS IoT FleetWise Agent logs.