This is the new AWS CloudFormation Template Reference Guide. Please update your bookmarks and links. For help getting started with CloudFormation, see the AWS CloudFormation User Guide.
AWS::IoTWireless::DeviceProfile LoRaWANDeviceProfile
LoRaWAN device profile object.
Syntax
To declare this entity in your AWS CloudFormation template, use the following syntax:
JSON
{ "ClassBTimeout" :Integer, "ClassCTimeout" :Integer, "FactoryPresetFreqsList" :[ Integer, ... ], "MacVersion" :String, "MaxDutyCycle" :Integer, "MaxEirp" :Integer, "PingSlotDr" :Integer, "PingSlotFreq" :Integer, "PingSlotPeriod" :Integer, "RegParamsRevision" :String, "RfRegion" :String, "RxDataRate2" :Integer, "RxDelay1" :Integer, "RxDrOffset1" :Integer, "RxFreq2" :Integer, "Supports32BitFCnt" :Boolean, "SupportsClassB" :Boolean, "SupportsClassC" :Boolean, "SupportsJoin" :Boolean}
YAML
ClassBTimeout:IntegerClassCTimeout:IntegerFactoryPresetFreqsList:- IntegerMacVersion:StringMaxDutyCycle:IntegerMaxEirp:IntegerPingSlotDr:IntegerPingSlotFreq:IntegerPingSlotPeriod:IntegerRegParamsRevision:StringRfRegion:StringRxDataRate2:IntegerRxDelay1:IntegerRxDrOffset1:IntegerRxFreq2:IntegerSupports32BitFCnt:BooleanSupportsClassB:BooleanSupportsClassC:BooleanSupportsJoin:Boolean
Properties
ClassBTimeout-
The ClassBTimeout value.
Required: No
Type: Integer
Minimum:
0Maximum:
1000Update requires: Replacement
ClassCTimeout-
The ClassCTimeout value.
Required: No
Type: Integer
Minimum:
0Maximum:
1000Update requires: Replacement
FactoryPresetFreqsList-
The list of values that make up the FactoryPresetFreqs value. Valid range of values include a minimum value of 1000000 and a maximum value of 16700000.
Required: No
Type: Array of Integer
Maximum:
20Update requires: Replacement
MacVersion-
The MAC version (such as OTAA 1.1 or OTAA 1.0.3) to use with this device profile.
Required: No
Type: String
Maximum:
64Update requires: Replacement
MaxDutyCycle-
The MaxDutyCycle value.
Required: No
Type: Integer
Minimum:
0Maximum:
100Update requires: Replacement
MaxEirp-
The MaxEIRP value.
Required: No
Type: Integer
Minimum:
0Maximum:
15Update requires: Replacement
PingSlotDr-
The PingSlotDR value.
Required: No
Type: Integer
Minimum:
0Maximum:
15Update requires: Replacement
PingSlotFreq-
The PingSlotFreq value.
Required: No
Type: Integer
Minimum:
1000000Maximum:
16700000Update requires: Replacement
PingSlotPeriod-
The PingSlotPeriod value.
Required: No
Type: Integer
Minimum:
128Maximum:
4096Update requires: Replacement
RegParamsRevision-
The version of regional parameters.
Required: No
Type: String
Maximum:
64Update requires: Replacement
RfRegion-
The frequency band (RFRegion) value.
Required: No
Type: String
Maximum:
64Update requires: Replacement
RxDataRate2-
The RXDataRate2 value.
Required: No
Type: Integer
Minimum:
0Maximum:
15Update requires: Replacement
RxDelay1-
The RXDelay1 value.
Required: No
Type: Integer
Minimum:
0Maximum:
15Update requires: Replacement
RxDrOffset1-
The RXDROffset1 value.
Required: No
Type: Integer
Minimum:
0Maximum:
7Update requires: Replacement
RxFreq2-
The RXFreq2 value.
Required: No
Type: Integer
Minimum:
1000000Maximum:
16700000Update requires: Replacement
Supports32BitFCnt-
The Supports32BitFCnt value.
Required: No
Type: Boolean
Update requires: Replacement
SupportsClassB-
The SupportsClassB value.
Required: No
Type: Boolean
Update requires: Replacement
SupportsClassC-
The SupportsClassC value.
Required: No
Type: Boolean
Update requires: Replacement
SupportsJoin-
The SupportsJoin value.
Required: No
Type: Boolean
Update requires: Replacement